ComfortKone Trial Fitting Example – TA121509
This patient was brought in by local practitioner for keratoconus fitting with ComfortKone. Topography confirmed keratoconus OU and trial lenses were selected according to Steepest “SimK Values”.
Topography OD
Topography OS
OD – Base Curve 6.60, Power -5.00, Diameter 8.5, A-Value 10
OS – Base Curve 6.30, Power -8.00, Diameter 8.5, A-Value 15
Evaluation showed mild central pool with a thin band of fluorescein around edges OU. Less edge clearance was noted on OS versus OD.
Fluorescein pattern OD

Fluorescein pattern OS

Conclusions: Base Curve fit is acceptable OU.
More edge lift is needed so higher A Values should be used.
Over-refraction was -.50 OD and -.75 OS.
Prescriptive lens specifications:
OD – Base Curve 6.60, Power -5.50, Diameter 8.5, A-Value 12
OS – Base Curve 6.30, Power -8.75, Diameter 8.5, A-Value 16